Basic Info
  • Model NO.: UF-100F
  • Type: Ultrasonic Flow Meter
  • Measuring Principle: Electrical Principles
  • Velocity: 0.03 - ± 32 M/S
  • Data Interface: RS-232 Serial Port
  • Specification: ISO, CE, SGS
  • Sensor: Clamp-on/External
  • Measuring Media: Liquid
  • Measure Size: Dn15~Dn6000
  • Power Supply: AC: 220V DC: 8~36
  • Trademark: Beifang
  • Origin: China
Product Description
Fixed Ultrasonic flow meter
1. Accuracy: Better than 1%
2. Repeatability: 0.2%
3. Certifiacte: EMC and LVD Compliance certificat

Ultrasonic flowmeter including follow types:
Fixed, Portable, Handheld type,
Flange, Insertion, Clamp-on sensor type,
Battery powered, Heat flow type ect.



Fixed Ultrasonic Flow Meter
The  specifications of our Fixed ultrasonic flow meter
Measuring Principle Ultrasonic wave transmission time difference principle, dual CPU working in parallel, 4-byte floating-point operations
Accuracy Better than ± 1.0 %
Repeatability 0.2%
Velocity 0.03-± 32 m/s
Measurement Period 0.5S
Display Backlit LCD can display 2x20 letters instantaneous flow, cumulative flow, velocity, time, calories and other data signal output at the same time etc.
Keypad 4x4-key membrane keypad with tactile feedback
Input Can input two current signals(such as: temperature, pressure, liquid level, etc. signals ) in order to achieve heat measurements or a dual-purpose machine
Output Electric current signal    4-20mA or 0-20mA, etc. RS 485 Impedance 0 - 1K, accuracy 0.1%
Isolated OCT output For frequency output (0-9, 999Hz)
Internal Alarm (Buzzer) User programmable
External Alarm Driver Alarm signal can be transmitted to Relay or OCT
output terminals to drive an externa alarm.  
Data Interface RS-232 serial port.
Power AC: 220V    DC: 8~36VDC or AC7-30V
Power Consumption < 2W
Work time Continuous
Environment Temperature -30-80 Degrees Celsius
Environment Humidity 85% RH

 

 

Product Features:
Product      Features 1. Bi-directional measurement, can measure the positive and negative, the net cumulative flow
2. Automatic memory before 64 days prior 64 months, the first 5 years of light product flow rate
3. Automatic memory 64 days before the working status of flow met er
4. Auto memory the former 64 times more time and power flows can be manual or automatic inspection in order to reduce the flow losses
5. Programmable volume (quantitative) Controller
6. Configure GPRS / GSM module enables remote monitoring and control